Schneider EasyPact EZC100B3050 50A 3P MCCB Cat A Uimp 6 kV.
3 Phase.
Protected poles : 3t
Network type : DC / AC
Rated current : 50 A at 40 °C
Rated insulation voltage ; 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage : 6 kV conforming to IEC 60947-2
Rated operational voltage : 550 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code : B
10 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
7.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
7.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity :
0.625 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
1.25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
1.875 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
1.875 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit technology : Thermal-magnetic
Trip unit rating : 50 A at 50 °C
Protection type : Short-circuit protection , Overload protection
Control type : Toggle
Mounting mode : Fixed
Mounting support : Backplate
Upside connection : Front
Downside connection : Front
Mechanical durability : 8500 cycles
Electrical durability : Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Connection pitch : 25 mm
Local signalling : Positive contact indication
Height : 130 mm
Width : 75 mm
Depth : 60 mm
Environment Standards : JIS C8201-2-2 ; EN/IEC 60947-2 ; EN/IEC 60947-1 ; GB/T 14048.2
IP20 conforming to IEC 60529
IK07 conforming to IEC 62262
New, harga per buah dengan ORIGINAL box.
3 Phase.
Protected poles : 3t
Network type : DC / AC
Rated current : 50 A at 40 °C
Rated insulation voltage ; 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage : 6 kV conforming to IEC 60947-2
Rated operational voltage : 550 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code : B
10 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
7.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
7.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity :
0.625 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
1.25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
1.875 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
1.875 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit technology : Thermal-magnetic
Trip unit rating : 50 A at 50 °C
Protection type : Short-circuit protection , Overload protection
Control type : Toggle
Mounting mode : Fixed
Mounting support : Backplate
Upside connection : Front
Downside connection : Front
Mechanical durability : 8500 cycles
Electrical durability : Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Connection pitch : 25 mm
Local signalling : Positive contact indication
Height : 130 mm
Width : 75 mm
Depth : 60 mm
Environment Standards : JIS C8201-2-2 ; EN/IEC 60947-2 ; EN/IEC 60947-1 ; GB/T 14048.2
IP20 conforming to IEC 60529
IK07 conforming to IEC 62262