Atur jumlah dan catatan
Stok Total: Sisa 10
Subtotal
Rp3.074.000
HONEYWELL / RESIDEO TF 830.3 control box Best
Rp3.074.000
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: Semua Etalase
HONEYWELL / RESIDEO TF 830.3 control box For 1- or 2-stage oil power burners up to 30kg/ h capacity and intermittent operations. Flame detection - Photoresistor MZ 770 S - Infrared-flicker detector IRD 1010.1 - UV solid state sensor UVD 970 APPLICATION RANGE The TF 830.3 or TF 832.3 oil burner safety control boxes are suitable to control and monitor oil power burner up to 30 kg/h capacity (approved and certified according to EN230). TYPES AVAILABE TF 830.3 1-stage operation post-ignition time ca. 20 sec. low voltage protection according to EN230 TF 832.3 2-stage operation post-ignition time 2-5 sec. low voltage protection according to EN230 CONSTRUCTIONAL FEATURES The control box circuitry is protected by a flame resistant, transparent plastic housing. It incorporates the thermomechanical, temperature compensated timer, flame check and reset circuits. Manual reset from lockout is provided by a push button with an integrated lockout signal lamp. A central fixing screw locks the control box to the wiring base. The wiring base and control box have a positive plug-in arrangement, making it impossible to achieve an incorrect connection between the two parts. A variety of cable entry points provides utmost flexibility of electrical wiring. APPLICATION NOTES 1. Flame control The following detectors can be used for flame control – For yellow oil flame photoresistor MZ 770 S – for blue or yellow flame infrared-flicker detector type IRD 1010.1 or as alternative the UV solid state sensor UVD 970. Using the photo resistor MZ 770 S, the no flame signal is generated at light levels below 3 Lux with respect to the operating cycle of the control. According to EN 230 stray light safety level has to be established in conjunction with the accompanying burner. Connecting the IRD 1010.1 or the UVD 970, the correct wiring has to be observed. 2. Burner control For burners without an oil solenoid valve, the burner motor has to be connected to terminal 5. 3. Low-voltage protection The start up of the burner can only take place if the mains voltage is higher than a limit which is 15% below nominal value. If the voltage drops below 160V, a start-up is prevented or – without allowing to release the fuel – the control box goes into lock out mode. 4. Safety The design and control sequence of the TF 830.3 and TF 832.3 control boxes comply with the currently applicable European standards and regulations. 6. Mounting and electrical wiring Wiring base – 3 earth terminals with additional terminal for burner earthing – 3 neutral terminals with internal permanent connection to neutral terminal 8 – 2 independant spare terminals (S1 and S2) – 2 slide-in plates and 2 easy knock out holes plus 2 knock out holes in the base bottom faciliate the base wiring. Jangan lupa tanyakan stok terlebih dahulu sebelum order. Kunjungi toko kami untuk melihat produk lainnya. Layanan Pengiriman yang tersedia next day, reguler, dan cargo Transaksi yang masuk hari Minggu dan Hari Libur Nasional akan kami proses keesokan harinya, Terima kasih sudah berkunjung di toko kami.
Ada masalah dengan produk ini?
ULASAN PEMBELI

Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan