LRE361, SCHNEIDER THERMAL OVERLOAD RELAY EASYPACT 55-70 A, CLASS 10A
Spec :
Range : EasyPact
Product or component type : Differential thermal overload relay
Relay application : Motor protection
Phase failure sensitivity : Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1
Product compatibility : LC1E80...95
Network type : AC
Network frequency : 50...60 Hz
Plate, with specific accessories
Rail, with specific accessories
Thermal overload class : Class 10A conforming to IEC 60947-4-1
Signalling function : Relay trip indicator
Thermal protection adjustment range : 55…70 A
Tripping threshold : 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Mechanical robustness : Shocks: 6 Gn for 11 ms conforming to IEC 60068-2-7
Vibrations: 3 Gn conforming to IEC 60068-2-6
[Ith] conventional free air thermal current : 5 A for signalling circuit
[Ue] rated operational voltage : <= 690 V AC
NOTE :
Mohon untuk menanyakan ketersediaan stock terlebih dahulu sebelum melakukan pengorderan barang.
Membeli = Setuju ya
Barang yang sudah dibeli tidak dapat DITUKAR atau DIKEMBALIKAN
LRE361, SCHNEIDER THERMAL OVERLOAD RELAY EASYPACT 55-70 A, CLASS 10A
Spec :
Range : EasyPact
Product or component type : Differential thermal overload relay
Relay application : Motor protection
Phase failure sensitivity : Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1
Product compatibility : LC1E80...95
Network type : AC
Network frequency : 50...60 Hz
Plate, with specific accessories
Rail, with specific accessories
Thermal overload class : Class 10A conforming to IEC 60947-4-1
Signalling function : Relay trip indicator
Thermal protection adjustment range : 55…70 A
Tripping threshold : 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Mechanical robustness : Shocks: 6 Gn for 11 ms conforming to IEC 60068-2-7
Vibrations: 3 Gn conforming to IEC 60068-2-6
[Ith] conventional free air thermal current : 5 A for signalling circuit
[Ue] rated operational voltage : <= 690 V AC